Raychem self-regulating heat trace cables consist of two parallel conductors embedded in a heating core made of semi-conductive polymer. The core is radiation-cross-linked to ensure long-term reliability and stable performance.
When electricity passes through the semi-conductive polymer core, heat is produced. In colder conditions, the core creates more electrical paths, increasing heat output where it is needed. As temperatures rise, fewer electrical paths are available, so the cable produces less heat and uses less energy.
Self-Regulating Heat Tracing: Built for Efficiency and Reliability
This ability to respond locally along the length of the cable makes self-regulating heat tracing an efficient and reliable technology for pipe freeze protection, process temperature maintenance, flow maintenance, roof and gutter de-icing, surface snow melting, hot water temperature maintenance, tank heating and floor heating. Because the cable reduces output when less heat is needed, it helps support safe operation, energy efficiency and long service life.
Raychem self-regulating heating cables are used across residential, commercial, infrastructure and industrial applications. As the inventor of self-regulating heat tracing technology, Chemelex has decades of experience in conductive polymer technology and a global installed base of heating cable systems protecting critical processes, places and people.
Chemelex’s most recent heating cable development is the High Power Retention (HPR) technology, resulting in a design life of at 30 years or more.
Do Self-Regulating Cables Still Need Controls?
Self-regulating heating cables still need controls. The cable can adjust heat output, but the controller manages the whole heat tracing system. It helps switch the system on only when heat is needed, monitor performance, and alert users to issues such as temperature changes, current levels, voltage or ground faults.
Together, self-regulating cables and heat tracing controls make the system safer, more efficient and easier to manage.