Raychem Data Center Solutions

Fire Rated Wiring

Reliable fire suppression systems to keep your data center protected.

Pyrotenax System 1850 Fire Rated Wiring Solutions

Data halls typically use pre action wet systems or dry pipe sprinkler systems, designed to meet NFPA 13 and NFPA 75 requirements. Data halls house high density IT equipment, generating significant heat and smoke, and are often 24/7 operational with limited human occupancy. Fires can cause catastrophic downtime and data loss, so sprinkler systems must balance life safety, asset protection, and operational continuity. Pyrotenax System 1850 wiring is a UL/ULC 2 hour fire rated mineral insulated (MI) copper sheathed cable that meets NFPA 13 requirements for fire pumps and other emergency circuits within data centers that must remain operational during a fire.

Ampacity Advantage – Pyrotenax System 1850’s construction gives it a unique ability to carry up to 4 times the current of conventional power wires. System 1850 is ideal for retrofit and other applications where increased power density is needed and there is limited space available.

Pyrotenax System 2000 and 2200 High Temperature Wiring Solutions for Power Generation Applications

Pyrotenax System 2000

System 2000 wiring is a mineral insulated, Alloy 825 sheathed cable with nickel clad copper conductors that allows continuous exposure to temperatures up to 1238°F (670°C) and can withstand rapid-rise temperature excursions to 2000°F (1093°C) for up to 30 minutes using stringent industrial fire test procedures. The sheath provides durability in areas where corrosives may be present and the nickel-clad copper conductors permit higher current ratings compared with nickel conductors making it ideal for SMR and other modern power generation applications.

Pyrotenax System 2200

System 2200 is a mineral insulated, Alloy 825 sheathed cable with solid nickel conductors that allows continuous exposure to temperatures up to 1238°F (670°C) and can withstand rapid rise temperature excursions to 2200°F (1200°C). Using stringent industry standard electrical test procedures, System 2200 can maintain electrical circuit integrity for up to 2 hours of exposure to an intense hydrocarbon fire. Also, ideal for SMR and other modern power generation for Data Center applications.


Our Solutions

Pyrotenax System 2000

Pyrotenax System 2000

Pyrotenax System 2200

Pyrotenax System 2200

Embedded Image

Pyrotenax

Fire Rated Wiring Solutions

Learn more about the advantages of Pyrotenax fire rated wiring systems.

Contact Us Today

Unsure where to start? For all your design, product and service needs, reach out to one of our data center experts today.

Data Center Fire Protection | Chemelex